Description:
CE certificate The Unique Innovationand on behalf of the top level in China. Vertical dual channel input, bandwidth 200MHz/100MHz/60MHz/40MHz; Sweep time base 50s/div ~ 1ns/div( or 5ns/div, 10ns/div);Maximum real time sampling 500Msa/s, 1Gsa/s. Functions of Recall, Zoom and Cursor; Auto measurement for waveform parameter;Math calculation; Auto edge pulse width external vedio trig mode; Record function; DMM function; RS232, built in lithium batteries.To observe waveform the in the travellingenvironmental and measure and store DC/AC voltage and resistor ect. Color screen.
Details:
Vertical system
|
42010
|
41005
|
|
|
|
Channel
|
CH1, CH2
|
|
Input coupling
|
AC, DC
|
|
Frequency width
|
200MHz
|
100MHz
|
100MHz
|
|
|
Rising time
|
≤1.75ns
|
≤3.5ns
|
|
|
|
Deflectioncoefficient
|
2mV/div~50V/div, 1-2-5, ±3%
|
|
Input impedance
|
1MΩ(±2%) //16pF(±2pF)
|
|
Max input voltage
|
400V(DC+ACpeak)≤400Hz
|
|
Vertical accuracy
|
3%±1 pixel, when 2mV/div ≤5%±1 pixel
|
|
Vertical resolution
|
8bits ADC
|
|
Common-mode rejection ratio
|
DC≥20:1
|
|
Display range
|
±4div
|
Open noise
|
≤0.4div
|
Horizontalsystem
|
Sweep time coefficient
|
Rolling 50s/div~100ms/div
|
Real time 50ms/div~25ns/div
|
Equivalent10ns/div~1ns/div
|
Sampling velocity
|
Real time: 40005 series 500MSa/s, Equivalent:10GSa/s
40010 series:1Gsa/s, equivalent25Gsa/s
|
Time resolution
|
40ps
|
Record length
|
50k
|
Storage depth
|
250k
|
Sampling mode
|
Real time, equivalent, average(2/4/8/64 four devisions can be set), peak value
|
Horizontalmode
|
Main time base, main time base+windows expansion (expand×2,×5,×10)
|
Cursor readout accuracy
|
± (1%read±1 pixel)
|
Display range
|
±5div
|
Trigger system
|
Trigger source
|
CH1, CH2, ext
|
Trigger mode
|
Norm, auto, auto-measure, single, edge, TV-V, TV-H, pulse width
|
Hi-freq inhibition
|
Attenuate signal>100KHz, trig sensitivity normal at DC ~10KHz
|
Low-freq inhibition
|
Attenuate signal<100KHz, the sensitivity normal for above 100KHz
|
Trigger level range
|
±4div
|
Ext.trigger
|
Input impedance:1MΩ(±5%)//20pF(±2pF)
|
Bandwidth:500KHz
|
Mode:auto,edge
|
Trig level:≤200mVp-p
|
Video trigger
|
TV-V:≥2div TV-H:≥2div
|
Memory
|
Quantity
|
5
|
Output interface
|
RS-232
|
Digital meter measure
|
Resolution
|
3-3/4
|
Input impedance
|
10MΩ(±1%)//15pF(±2pF)
|
Voltage measure
|
Range: 400mV(0.1mV), 4V(0.001V), 40V(0.01V), 400V(0.1V)
|
DC accuracy (full):±2%
|
AC accuracy (full):±(2%readout±3pixel); Frequency.50Hz~1KHz
|
Resistancemeasure
|
Range400Ω(0.1Ω), 4kΩ(0.001kΩ), 40kΩ(0.01kΩ), 400kΩ(0.1kΩ), 4MΩ(1kΩ), 20MΩ(0.01MΩ)
|
Accuracy (full):Less than 20MΩ±(2%readout±5pixel)
At 40MΩ±(5%readout±5pixel)
|
Current measure
|
Range4mA, 40mA, 4A
|
Accuracy (full): At 40mA, 400mA, 4A (±3%+10words)
At 4mA, 4A (±5%+20words)
|
Short circuit measure
|
Tell resistor < 40Ω(beak)
|
Diode measure
|
Max readout 2V
|
Screen
|
Display screen
|
5.7 inch LCD 320×240dots , backlight adjustable
|
Waveform display region
|
Vertical 8div×25dots/div, horizontal10div×25dots/div
|
Physical characters
|
Power supply
|
AC100V~240V/45Hz~60Hz
|
Lithium battery
|
7.2V/4A, work time last 4 hours
|
Dimension
|
64H×169W×254Dmm
|
Weight
|
About 1.8kg
|
|