What's New
12
Our Catalogs
1

  • product.jpg
  • product.jpg

FACTORY POWER DISTRIBUTION SYNTHETIC AUTOMATION TRAINING SYSTEM

PN:0203020102

Name
*Email
Phone
*Country
*Comment
*Required Fields
  • Send an E-mail
  • Call CEIEC
  • Send a Letter or Fax

  • Description
  • Scope of Supply
  • Literature
  • Accessories
  • Downloads

Description:

A factory substation with two-line 35kV lead-in power supply is simulated, which one line is lead to the branch factories, the other is sent to workshop substations after being reduced to 10kV by step-down transformer. Functions: 1. Simulation of factory substation, low voltage load and high voltage load. 2. Simulation of the three stating modes of motor (power loading). 3. Intelligent control device: microprocessor-based line protection, microprocessor-based motor protection, microprocessor-based backup power supply auto-switch, intelligent reactive compensation, etc. Microprocessor-based line protection device: functions of 3-section over current protection, low-voltage latching current protection, single-phase ground protection, inverse time lag over-current protection and cooperation of step over current protection and automatic reclosing. The measuring accuracy level of voltage and current are 0.5. Microprocessor-based motor protection device: Functions of current quick-break protection, over-current protection, current inverse time lag protection, zero-sequence over current protection and low-voltage protection, etc. The measuring accuracy level of voltage and current are 0.5. Microprocessor-based backup power supply auto-switch device: three modes (lead-in line, bus and emergency); on-line setting of the auto-switch time and voltage; monitoring of 12-channel analog and 10-channel switching value. The measuring accuracy level of voltage and current are 0.5.

Details:

Comprising analog line and factory substation unit, dummy load unit, factory line protection unit, motor

protection unit, reactive compensation unit, backup power supply auto-switch unit, monitoring unit and

instrumentation unit.

1. Analog line and

factory substation unit

Including line reactance, breaker, disconnection switch and transformer.

2. Dummy load unit

Comprising high voltage load and low voltage load. The high-voltage load is composed

of motor set, and low-voltage load includes lighting load, power load, cooling fan,

emergency lighting, fire fighting apparatus, ventilation and explosion prevention.

3. Factory line

protection unit

Comprising fault setting circuit, voltage transformer, current transformer, factory

microprocessor-based line protection device and stopwatch.

4. Motor protection

unit

Comprising motor set, frequency converter, excitation circuit and motor starting

circuit.

5. Reactive

compensation unit

Comprising intelligent reactive compensation device, compensation capacitance,

compensation indicator circuit and RC absorption circuit.

6. Backup power supply

auto-switch unit

Comprising power failure setting unit, voltage transformer, current transformer,

microprocessor-based backup contention switch.

7. Monitoring unit

Comprising touch screen (display area: 10.4), PLC controller and intelligent sampling

module.

8. Instrumentation

Comprising seven AC voltmeters and six AC ammeters.

Name Range Accuracy level Qty.

AC voltmeter 0~40kV 1.5 3

AC voltmeter 0~500V 1.5 4

AC ammeter 0~50A 1.5 6

Lab exercises:

Microprocessor-based line protection

1. Microprocessor-based line protection device

2. Current quick-break protection without time lag

3. Current quick-break protection with time lag

4. Over current protection with constant time lag

5. Over current protection with inverse time lag

6. Interlock protection of current and voltage

7. Single-phase ground protection

8. Stepped over current protection and automatic relcosing former acceleration

9. Stepped over current protection and automatic relcosing back acceleration

Auto device in power distribution system

10. Backup power supply auto-switch device

11. Backup power supply auto-switch

12. Low voltage load reduction

13. Reactive compensation device

14. Reactive automotive compensation

15. Simulation of factory power supplying switching operation

Power distribution automation

16. Orientation, isolation of line faults and auto-restoring of power supply

17. Detection of line parameters

18. Line reactive control

19. Line voltage adjustment

20. Line voltage/reactive integrated control

SCADA

21. Telemeter, telecontrol, teleregulation and telesignal

Computer

C3.06/256M/80G/DVD/17 pure flat




No.1, Bei Yi Xiang, Damucang Hutong, Xidan, Beijing P.R.C.100032

Copyright © 2009 China Educational Instrument & Equipment Corp. All rights reserved.

Damucang Hutong, Xidan, Beijing P.R.C.100032

Name
*Email
Phone
*Country
*Comment
*Required Fields
  • Send an E-mail
  • Call CEIEC
  • Send a Letter or Fax