What's New
12
Our Catalogs
1

  • product.jpg
  • product.jpg

POWER SUPPLY AND DISTRIBUTION SYNTHETIC TRAINING SYSTEM

PN:0203020001

Name
*Email
Phone
*Country
*Comment
*Required Fields
  • Send an E-mail
  • Call CEIEC
  • Send a Letter or Fax

  • Description
  • Scope of Supply
  • Literature
  • Accessories
  • Downloads

Description:

The system can fulfill the lab exercises as follow:

1. Relay training in power distribution

(1) Typical current relay

(2) Typical voltage relay

(3) Typical middle relay

(4) Typical time relay

(5) Signal relay

(6) Differential relay

2. Relay protection training in power distribution

(1) Over current protection with time limit in power distribution

(2) Low-voltage start over current protection in power distribution

(3) Current quick break protection in power distribution

(4) Current reverse time limit protection in power distribution

(5) Over current protection in distribution transformer

(6) Current quick break protection in distribution transformer

(7) Over load protection in distribution transformer

(8) Longitudinal differential protection in distribution transformer

3. Secondary loop and automatic device training in power distribution

(1) control and signal loop of breaker

(2) Insulation monitoring device for 6~35KV system

(3) Reclosing of power distribution system

(4) Over current protection and auto reclose

(5) Over current protection and late-reclosing acceleration

(6) APD circuit of bus back-up power auto switch

(7) APD circuit of lead-in back-up auto switch

(8) Transformer voltage adjustment with load

(9) Manual/auto power factor compensation

4. Monitoring training in power distribution system

(1) System electricity monitoring and load curve plotting

(2) Remote control and signal acquisition of breaker

(3) Voltage reactive auto-adjust in substation

5. PLC training in Power distribution protection

(1) Over current protection with time limit

(2) Over current protection in low-voltage start

(3) Current quick break protection

(3) Over current protection of transformer

(4) Over load protection of transformer

(5) Over current protection and reclosing

(6) Over current protection and late-reclosing acceleration

(7) Space power source automatic switch

Details:

Including:

1. Electrical primary circuit panel: two way 10kV input, high/low sides are both

circuit of busbar, all the switching components has the position indictor.

2. Electrical control simulation panel: high-voltage electrical control simulation

panel, low-voltage electrical control simulation panel, intelligent electricity

acquisition, intelligent reactive power compensation device, current transformer,

voltage transformer, resistance/inductive load, analog breaker and isolation switching

components.

3. Relay protection and monitor: power supply for instrument, secondary signal for

mutual inductor, general changeover switch, breaker trip and closing signal and control

loop, word indicator and blaming buzzer, PLC, short circuit insertion module.

4. Instrument component: DC digital ammeter, DC digital voltmeter, AC RMS ammeter,

AC RMS voltmeter, digital stopwatch.

5. Relay components

6. 9kVA 3-phase auto transformer

7. Monitoring software

8. Accessories and connecting wires

9. Operating instructions and laboratory manual