Description:

The system is designed for the experiments covering courses of "Power distribution technology", "factory power distribution", "Power distribution automation", "Electric power system relay protection", which is suitable for the teaching of electric power and electric courses.

Details:

1. Typical primary system, secondary device and monitoring meters

2. Relay protection with PLC functions

3. Industrial configuration software programming, for monitoring of power distribution system

Lab exercises:

Common relay characteristics of power distribution system

1. Typical current relay characteristics

2. Typical voltage relay characteristics

3. Typical intermediate relay characteristics

4. Signal relay characteristics

5. Differential relay characteristics

Relay protection of power distribution system

6. Over-current protection of power distribution circuit with time lag

7. Low-voltage start over-current protection of power distribution circuit

8. Current quick-break protection of power distribution circuit

9. Current reverse time-lag over-current protection of power distribution circuit

10. Over-current protection of power distribution transformer

11. Current quick-break protection of power distribution transformer

12. Over-load protection of power distribution transformer

13. Longitudinal differential protection of power distribution transformer

Secondary loop and automation device of power distribution system

14. Control and signal loop of breaker

15. Insulated monitoring device circuit of 6~35KV system

16. Primary reclosing of power distribution system

17. Integration of circuit over-current protection and automatic reclosing

18. Integration of over current protection and automatic relcosing back acceleration

19. Dual power back-up APD circuit

20. Dual power lead-in back-up APD circuit

21. Voltage control of electric power transformer on load

22. Manual/automatic power factor compensation

Microprocessor monitoring of power distribution system

23. System power monitoring and load curve measurement

24. Remote control and signal acquisition of breaker

25. Substation voltage reactive comprehensive automatic control

Application of PLC in power distribution protection control

26. Over-current protection of circuits with time lag

27. Low-voltage start over-current protection of circuits

28. Current quick-break protection of circuits

29. Over-current protection of transformer

30. Over-load protection of transformer

31. Circuit over-current protection and automatic reclosing

32. Circuit over-current protection and automatic reclosing back acceleration

33. Backup power supply automatic connection

Simulation of power supply and cutoff of power distribution station

Telemeasurement, telecontrol and telesignal