1.Modular structure design, many kinds of power electronics devices, thyristor firing circuits and controller are available.

2. Full protections: voltage and current mode leakage protection device; monitoring and short-circuit protection for the power supply output; timer & alarm recorder for students examining.

3. Abundant lab exercises

Details:

The equipment is composed of power control panel, many experiment units and guide rail motor.

DJK01 power control panel

1. Phase loss/over-voltage indication and phase sequence check

The indicator lamp lights up of there is any phase loss and it alarms if the voltage exceeding 250V.

2. AC power supply (with over-current protection)

3-phase power supply 200V@3A for DC speed regulation

3-phase power supply 240V@3A for AC speed regulation

3. High-voltage DC power supply

Excitation power: DC 220V @0.5A with short-circuit protection

4. Digital instruments

AC digital voltmeter: accuracy: class 1.0, used for 3-phase power grid voltage measurement;

One RMS value AC digital voltmeter: measuring range: 0~500V, auto ranging, accuracy: class 0.5, 3 and 1/2 -digit

display, used for voltage indication;

One RMS value AC digital ammeter: measuring range: 0~5A, auto ranging, accuracy: class 0.5, 3 and 1/2 -digit display,

with function of over-range alarming & indication and power cutting off, used for current indication;

One DC digital voltmeter: measuring range: 0~300V, input impedance: 10MΩ, accuracy: class 0.5, 3 and 1/2 -digit

display, used for voltage indication;

One DC digital ammeter: measuring range: 0~5A, accuracy: class 0.5, 3 and 1/2 -digit display, with function of

over-range alarming & indication and power cutting off, used for current indication.

5. Safety

Isolated transformer: there are RCCB, key switch, contactor, isolated transformer for isolating from the power

grid for safety;

Voltage-mode leakage protector 1: leakage protection on the circuit before isolated transformer, cutting off the

power if there is leakage;

Voltage-mode leakage protector 2: leakage protection on the circuits after isolated transformer and

experimental connection, cutting off the power if there is leakage, and alarming;

Current-mode leakage protector: cutting off power if the leakage current exceeding the threshold value;

Fully shrouded connections for protection against hazard of electric shock

6. Timer/alarm recorder

Functions of lab service supervision including lab time set, alarming at expire time and faults history are

provided

7. Additional facilities

12-way, 10-way, 4-way and 3-way sockets for power supply to application units; single-phase and 3-phase outlet

on both sides.

Kit

The kit consists of rotations encode and a digit-displayed rotations speed meter. All

components are easy machine coupling on a slide-rail base.

3-phase variable resistor

Three banks Used for loading purpose

Thyristor bridge

Anti-parallel 3-phase bridges with over current/voltage protection. Firing interface,

inductive load, voltmeter and ammeter are provided.

Firing circuit of 3-phase bridge

Used with Thyristor bridge

SCR firing circuits (single/3-phase)

Containing firing circuits of UJT, sin wave synchronous phasing, saw-tooth phasing.

DC Motor control system (1)

Containing modules: set up (G), current feedback and over current protection (FBC+FA), speed

conversion (FBS), inversion (AR), isolation (TVD) and controller (1/2); Observing effects of

controller's parameters on system performance

DC Motor control system (2)

Containing modules: torque polarity (DPT), logic controller (DLC), zeroing detector (DPZ),

carrying out the experiment of reversible DC motor speed control without circulating current.

DC chopper

Comprises chopper and firing circuit

Components

Including reference, over voltage protection resistors (Delta connected), diodes.

Power devices

Containing SCR, MOSFET, IGBT, GTR. It's used with DJK06 for test of characteristics for test

of device drives.

Variable resistors, capacitors

For configuration of current/speed controllers

Single-phase AC power supply & variable load

Comprises a single-phase variable autotransformer (0~250V/0.5kVA), a rectifying filtering

circuit and 0~180Ω/1.3A (series) or 0~45Ω/2.6A (parallel) regulable resistance

3-phase transformer and 3-phase uncontrolled rectification circuit

Comprises a 3-phase core-transformer (primary coil voltage 127V, secondary coils voltages are

63.6V and 31.8V), 3-phase uncontrollable rectifying circuit

DC generator

220W/200V 1600n/min insulated level E

DC shunt motor

185W/220V 1600n/min insulated level E

3-phase wound-rotor induction motor

120W/220V(Y) 1380n/min insulated level E

Additions to wound rotor induction motor

Used together with 3-phase wound-rotor induction motor.

Connection leads

For connections between control panel mounted application units, the leads are fitted with

Shrouded connectors and made from soft isolated cable.

Lab exercises:

Power electronics technology

1. Unijunction transistor firing circuit

2. Sine wave synchronous phase-shift firing circuit

3. Saw-tooth wave synchronous phase-shift firing circuit

4. Siemens TCA785

5. Single-phase half wave controlled rectification

6. Single-phase half-controlled rectification bridge

7. Single-phase bridge full-controlled rectification and active inversion circuits

8. 3-phase half wave controlled rectification

9. 3-phase bridge half-controlled rectification

10. 3-phase half wave active inversion circuits

11. 3-phase bridge full-controlled rectification and active inversion circuits

12. Single-phase AC voltage control

13. 3-phase AC voltage control

14. DC chopper circuits

15. SCR characteristics

16. Gate-Turn-off Thyristor (GTO) characteristics

17. Power MOSFET characteristics

18. Giant transistor (GTR) characteristics

19. Insulated-gate bipolar transistor (IGBT) characteristics

DC motor speed control

20. Parameters and characteristics test of the Thyristor-controlled DC motor drive system

21. Commissioning of the control blocks (SCR) of Thyristor-controlled DC motor drive system

22. Single-loop non-reversible DC motor drive system with speed/current/voltage feedback

23. Double-loop non-reversible DC motor drive system

24. Reversible Thyristor-controlled DC motor drive system with non-circulating current

AC motor speed control

25. Voltage/speed control system of double closed-loop 3-phase induction motor

26. Cascade speed control system of double closed-loop 3-phase induction motor

AC power supply

3-phase DC 200V/3A

3-phase AC 240V/3A

DC power supply

220V/0.5A, with output short-circuit protection

AC digital voltmeter

Power mains input line voltage can be registered, the accuracy is 1.0%

TRMS AC digital voltmeter

Measuring range: 0~500V, auto switching, accuracy 0.5%, 3 and 1/2-digit displayed

TRMS AC digital ammeter

Measuring range: 0~5A, auto switching, accuracy 0.5%, 3 and 1/2-digit displayed, with over-ranging alarm, indicating and power supply cutoff protections.

DC digital voltmeter

Measuring range: 0~300V, 3 and 1/2-digit displayed, input impedance: 10MΩ, accuracy: 0.5%

DC digital ammeter

Measuring range: 0~5A, accuracy 0.5%, 3 and 1/2-digit displayed, with over-ranging alarm, indicating and power supply cutoff protections.

3 and 1/2-digit digital multimeter

1. DC voltage: 200mV/2V/20V/200V/1000V ±(0.5%+3)

2. AC voltage: 2V/20V/200V/750V ±(0.8%+5)

3. DC current:20uA/2mA/200mA/20A ±(1.5%+3)

4. AC current: 2mA/20mA/20A ±(1.5%+5)

5. resistance: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ ±(0.8%+5)

6. conductance: (0.1-100)nS ±(1.0%+30)

7. capacitance: 20nF/200nF/20uF/200uF ±(4.0%+10)

8. frequency: 20kHz ±(1.5%+25) temperature: -40oC-1000oC ±(0.75%+3)

9. Special function: diode test, triode test, on/off alarm, low-voltage display, data hold, self-turning off, functional protection, self-recovery insurance, shakeproof, 10MΩ input impedance, 3 times/s sample rate, 40-400Hz AC frequency response, manual operation and the maximum display is 1999.

25M two-channel digital oscilloscope

1. Homochromy LCD, two-channel

2. 250 MSa/s real-time sampling rate, effective sampling rate: 50 GSa/s, Waveforms capture rate 1000/s

3. Digital filter and waveforms recording

4. Cursor measurement including manual mode, follow mode and auto measurement mode

5. 10-group waveforms, 10-group set, storage and reappearance

6. Waveforms operation

7. Edge, video, pulse and delay triggering functions

8. Embedded FFT frequency spectrum analysis

9. Automatic calibration function




No.1, Bei Yi Xiang, Damucang Hutong, Xidan, Beijing P.R.C.100032

Copyright © 2009 China Educational Instrument & Equipment Corp. All rights reserved.

Damucang Hutong, Xidan, Beijing P.R.C.100032

Name
*Email
Phone
*Country
*Comment
*Required Fields
  • Send an E-mail
  • Call CEIEC
  • Send a Letter or Fax