Mounting panel design for components facilitates operating and replacing components, and features expansion ability. In addition, typical and practical hands-on exercises can be performed
|
The system is 3-phase 4-wire AC voltage operated
|
Available voltage type and current type leakage protections ensure the human safety.
|
All devices and components have been brought out to terminals to avoid damage to the components caused by repeated exercises
|
The workbench allows two trainees operation simultaneously.
|
The workbench features two independent power supplies controlled by start/stop buttons and emergency stop button, short-circuit protection is available for the power output.
|
| Supplies 380V line voltage and 220V phase voltage, provides several single-phase and 3-phase power sockets.
|
| Comes with four 1N5408 diodes for dynamic braking circuit.
|
| Contains three 75Ω/75W power resistors for reduced voltage starting circuit, and one 10Ω/25W power resistor for dynamic braking circuit.
|
| Provides a 2-pole RCCB, two 3P fuses, a knife switch, and a single-phase watt-hour meter.
|
| Includes two Edison lamp holders, three switch boxes, a ballast, a starter, and a fluorescent lamp.
|
| Offers 3 AC ammeters and 3 current transformers.
|
| Comprises an AC voltmeter, a 3-phase power factor meter, and a voltage indication switch.
|
| Contains a 3-phase 3-wire active watt-hour-meter.
|
| Supplies a 3-phase 4-wire active watt-hour-meter
|
| Provides a 3-phase 4-wire reactive watt-hour-meter.
|
| Comes with 3-phase resistive load and 3-phase capacitive load.
|
|
Lamp control with a switch and socket (incandescent lamp, fluorescent lamp, and 2-pole RCCB)
|
Lamp control with two 2-gang switches (incandescent lamp, fluorescent lamp, and 2-pole RCCB)
|
Lamp control with three switches (incandescent lamp, fluorescent lamp, and 2-pole RCCB)
|
Connection of fluorescent lamp
|
Connection of incandescent lamp control circuit with sound control switch
|
Connection of incandescent lamp control circuit with touch delay switch
|
Connection of incandescent lamp control circuit with PIR switch
|
Direct connection of single-phase watt-hour meter
|
CT connection of single-phase watt-hour meter
|
Connection of voltmeter and ammeter
|
3-phase voltage measurement using universal change-over switch and voltmeter
|
Connection of single-phase control circuit with a current transformer
|
Wye connection of three current transformers
|
Delta connection of three current transformers
|
Connection of 3-phase power factor meter
|
Connection of 3-phase 3-wire active watt-hour meter
|
CT connection of 3-phase 3-wire active watt-hour meter
|
Connection of 3-phase 4-wire active watt-hour meter
|
CT connection of 3-phase 4-wire active watt-hour meter
|
Connection of 3-phase 4-wire reactive watt-hour meter
|
CT connection of 3-phase 4-wire reactive watt-hour meter
|
|
DC voltage: 200mV/2V/20V/200V/1000V ±(0.5%+3)
|
AC voltage: 2V/20V/200V/750V ±(0.8%+5)
|
DC current: 20μA/2mA/200mA/20A ±(1.5%+3)
|
AC current: 2mA/20mA/20A ±(1.5%+5)
|
Resistance: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ ±(0.8%+5)
|
Conductance: (0.1-100)nS ±(1.0%+30)
|
Capacitance: 20nF/200nF/20μF/200μF ±(4.0%+10)
|
Frequency: 20kHz ±(1.5%+25) temperature: -40oC-1000oC ±(0.75%+3)
|
Other functions: diode test, transistor test, continuity buzzer, low battery indication, data hold, auto shutdown, resettable fuse protection, shockproof protection, input impedance 10MΩ, sampling rate: 3 S/s, AC frequency response: 40-400Hz, manual ranging, max. reading: 1999 ( -digit)
|
CONFIGURATION:(As per one set)
|
| |
Tools and connecting leads
| |
User's manual and other technical materials
| |