Description:
This equipment is designed for experiments covering course of "Circuit analysis", "fundamentals of electrical engineering", "electrical engineering", "digital electronics", "analog electronics", "motor control" and "relay control" which addresses the requirements of colleges or vocational schools.
Details:
It consists of control panel, desk, equipment kit and 3-phase squirrel-cage asynchronous motor.
3-phase variable autotransformer 0-450v
Single-phase variable autotransformer 0-250v
Three AC pointer type voltmeters for input or output switched measurements
functions of over current, short circuit protection and leakage protection provided
2. Fluorescent lamps: 220V@30W, the terminals are connected to the panel. One or lighting and the other for
experiment.
Function of lab service supervision including lab time set, alarming at expire time, faults history
4. One RMS value AC digital voltmeter: 0~500V measurement with auto judging & ranging, accuracy: class 0.5, 3 and 1/2 -digit display.
5. DGJ-03 Fundamentals of electric
Provides Kirchhoff's law, superposition principle, Norton theorem, two-port network, Reciprocity theorem,
R LC series resonant circuits, RC series/parallel frequency selective network of first-order and second-order
dynamic circuit
Capacitors, resistors, diodes, triodes, zener diode, potentiometes and 12V signal lamp, regulable resistors:
0~99999.9Ω/2W.
Provides single-phase, 3-phase load, fluorescent lamp, transformer, mutual inductance and wattmeter.
Six incandescent lamps, capacitors, 30W fluorescent lamp ballast, starter, iron-core transformer, current
sockets etc.
8. DGJ-07-2 AC digital millivoltmeter, power meter and power factor meter
DSP based intelligent meter for measurements of watt, power factor with function of data recording
Voltage/current ranges: 0-450V/0-5A
AC digital millivoltmeter
Measuring range: 0.2mV~600V(RMS value), ranges of it: 200mV, 2V, 20V, 200V, 600V, with the functions of
over-range alarming and turn-off the power automatically,
Frequency range: 10Hz~600kHz
| | 1.Application of instruments and calculation of measuring error
2. Instruments measuring error reduction
3. V-I characteristics plotting of linear & nonlinear circuit components
4. Potential & voltage measuring and potential diagram plotting
5. Demonstration of Kirchhoff's law and troubleshooting
6. Demonstration of superposition principle and troubleshooting
7. Equivalent transform between voltage source and current source
8. Demonstration of Thevenin theorem
9. Demonstration of Norton theorem
11. Demonstration of Reciprocity theorem
12. Research on controlled sources (VCVS, VCCS, CCVS and CCCS)
13. Observation and measurement of typical electrical signal
14. Response testing of first-order RC circuits
15. Response testing of second-order RC circuits
16. Impedance characteristics measurement of RLC components
17. Characteristics testing of RC series & parallel frequency selective network
18. Research on R LC series resonant circuits
19. AC circuit equivalent parameters measurement
20. Research on the phasor of sinusoidal steady-state AC circuits
22. Characteristics testing of single-phase iron-core transformer
23. Voltage and current measurement of 3-phase AC circuits
24. Calibration of single-phase wattmeter
25. Measurement of power factor and phase sequence
| DC stabilized power
supply
| 0.0~30V/1A continuous adjustable power supply with short-circuit protection and
auto-recovery function for each circuit
| Adjustable constant
current source
| 0~200mA continuous adjustable constant current source, stepped into 2mA, 20mA and
200mA with the function of output open-circuit or short-circuit protection and 0.1%
adjustment accuracy, load reliability-4and change rate-4.
| | With two calibrate pointer(red, black) , measuring range: 0~500V, stepped into 10V,
30V, 100V, 300V, 500V.
With the function of over-range alarming and turn-off power automatically.
| | With two calibrate pointer(red, black) , measuring range: 0~5A, stepped into 0.3A,1A,
3A, 5A.
With the function of over-range alarming and turn-off power automatically.
| | Measuring range: 0~200V, is stepped into 200mV, 2V, 20V, 200V.
With the function of over-range alarming and turn-off power automatically.
| | Measuring range: 0~2000mA, is stepped into 2mA, 20mA, 200mA, 2000mA .
With the function of over-range alarming and turn-off power automatically.
| Single/three-phase
power, power factor
meters
| Constructed by microprocessor, high-speed A/D conversion chip and fully
digit-displayed circuits. Intelligent control is obtained by keys and digit display.
The sample signal of measured voltage and current are sent to DSP after A/D
conversion for positive/active power calculation. Measurement of single/three-phase
power with accuracy of grade 0.5 and ranges of voltmeter and ammeters are 450V, 5A.
also, data can be recorded and inquiry. The total power is obtained by sum of P1+P2.
| RMS value AC digital
millivoltmeter
| Accuracy measurement of every kind of complex waveform.
Voltage measurement range: 0.2mV~600V (RMS value), accuracy: ±1%,overlapping in
five ranges 200mV, 2V, 20V, 200V, 600V, controlled by keys, with 3 and 1/2-digit display
and over-range alarming, indication and power cutoff. Frequency measurement range:
10Hz~600kHz, input impedance: 1 MΩ, input capacitance:
| | Frequency range 0.2Hz~2MHz overlapping in seven ranges and frequency adjustment rate
is 0.1~1; output waveform: sine wave, square wave, triangle wave, pulse wave, ramp
wave; output impedance: 50Ω; output signal type: FM/frequency sweep, and types of
sweep: linear and logarithm with rate of 5s~10ms; output amplitude: 20Vp-p (1MΩ),
10Vp-p (50Ω); with output short-circuit protection which bearing ±35V for one
minute; adjustment of degree of symmetry: 20%~80%.
| 20M two-channel
analog oscilloscope
| 1. Deflection factor: 5mV/DIV-5V/DIV overlapping in 10 ranges
2. Vertical mode: CH1, CH2, ALT, CHOP, ADD
| 3 and 1/2 -digit digital
multimeter
| 1. DC voltage: 200mV/2V/20V/200V/1000V ±(0.5%+3)
2. AC voltage: 2V/20V/200V/750V ±(0.8%+5)
3. DC current:20uA/2mA/200mA/20A ±(1.5%+3)
4. AC current: 2mA/20mA/20A ±(1.5%+5)
5. resistance: 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ ±(0.8%+5)
6. conductance: (0.1-100)nS ±(1.0%+30)
7. capacitance: 20nF/200nF/20uF/200uF ±(4.0%+10)
8. frequency: 20kHz ±(1.5%+25) temperature: -40oC-1000oC ±(0.75%+3)
9. Special function: diode test, triode test, on/off alarm, low-voltage display, data
hold, self-turning off, functional protection, self-recovery insurance, shakeproof, 10MΩ input impedance, 3 times/s sample rate, 40-400Hz AC frequency response, manual
operation and the maximum display is 1999.
|
|