What's New
12
Our Catalogs
1

  • product.jpg
  • product.jpg

CURRENT ILLUMINATION CHARACTERISTIC LABORATORY APPARATUS OF PHOTO SENSOR

PN:0201022500

Name
*Email
Phone
*Country
*Comment
*Required Fields
  • Send an E-mail
  • Call CEIEC
  • Send a Letter or Fax

  • Description
  • Scope of Supply
  • Literature
  • Accessories
  • Downloads

Description:

In optical experiment, a photo sensor is necessary for measurements such as the illuminance of a position, luminous intensity of light source, light distribution of diffraction and interference, optical fiber optics measuring, extinction position and intensity of polarized light etc. The photo sensor is an element that is capable of converting the physics quantity of light intensity into electricity quantity. It is an important apparatus to be applied on modern optical measurement. Therefore, the experiment of current illumination characteristic of photo sensor is one of essential physical experiment in colleges and universities. The type current illumination characteristic laboratory apparatus of photo sensor is an improved one based on the type A, which embodies the following advantages:

1. Free adjustable in luminous intensity of light source by request of experiment; selectable in dc power supply with different voltage for it is equipped with several sets of power supply. It is reliable and easy in adjustment.

2. There four kinds photo sensors for selection: silicon photocell, light-sensitive resistor,light-sensitive diode and photistor etc. the apparatus is rich and varied in experimental content and high in availability.

The apparatus is capable of doing the following experiments:

1. Measure current illumination characteristic of silicon photocell;

2.Measure current illumination characteristic of light-sensitive resistor;

3. Measure current illumination characteristic of light-sensitive diode;

4. Measure current illumination characteristic of photistor.

Details:

Light source (Osram lamp):

illuminance 0-300Lx.

Dc power supply:

±2V, ±4V, ±6V, ±8V, ±10V, ±12V, six grades; output current:

Dc digital voltmeter:

range 1.9999V; resolution 0.0001V; Range 19.999V resolution 0.001V

Scaled digital voltmeter:

0-200mV±0.1%; resolution 0.01mV




No.1, Bei Yi Xiang, Damucang Hutong, Xidan, Beijing P.R.C.100032

Copyright © 2009 China Educational Instrument & Equipment Corp. All rights reserved.

Damucang Hutong, Xidan, Beijing P.R.C.100032

Name
*Email
Phone
*Country
*Comment
*Required Fields
  • Send an E-mail
  • Call CEIEC
  • Send a Letter or Fax